Brass Static Balance Valve with Threaded Connection and ISO9001 Certification for HVAC Systems

Ürün Ayrıntıları

Menşe yeri: Çin

Marka adı: JGPV

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 1 takım

Ambalaj bilgileri: Kontrplak kutusu güvenlik paketleme

Teslim süresi: 14 gün

Ödeme koşulları: L/C,T/T,Western Union

Yetenek temini: Ayda 500 Set

En İyi Fiyatı Bulun
Vurgulamak:

Brass Static Balance Valve

,

Threaded Static Balance Valve

,

ISO9001 Certified Brass Valve

Başvuru::
Genel
Sertifika::
ISO9001, ISO14001
Orta Tip::
Su, buhar ve yağ vb.
Bağlantı::
Dişli / flanşlı / kaynaklı
Standart veya standart dışı::
Standart
Akış yolu::
İki yönlü
Çalıştırma::
Manuel, elektrik, pnömatik, otomatik
Sızdırmazlık Performansı::
Sızdırmazlık
Çalışma Sıcaklığı::
Normal sıcaklık ve yüksek sıcaklık
Basınç Uygulaması::
normal basınç
Kalite Garantisi::
18 ay
Başvuru::
Genel
Sertifika::
ISO9001, ISO14001
Orta Tip::
Su, buhar ve yağ vb.
Bağlantı::
Dişli / flanşlı / kaynaklı
Standart veya standart dışı::
Standart
Akış yolu::
İki yönlü
Çalıştırma::
Manuel, elektrik, pnömatik, otomatik
Sızdırmazlık Performansı::
Sızdırmazlık
Çalışma Sıcaklığı::
Normal sıcaklık ve yüksek sıcaklık
Basınç Uygulaması::
normal basınç
Kalite Garantisi::
18 ay
Brass Static Balance Valve with Threaded Connection and ISO9001 Certification for HVAC Systems
Static Balance Valve - Brass Threaded Connection
Static Balance Valve Brass Threaded Thread
Product Overview

For static imbalance problems in HVAC systems, installing a balance valve with dedicated intelligent instrument debugging effectively eliminates residual pressure head in circuits, ensuring each loop achieves design flow rates.

This specialized function valve features excellent flow regulation characteristics with a linear relationship between relative flow rate and relative opening. It includes precise valve opening indication (minimum reading: 1% of full opening), reliable opening locking memory device, shut-off functionality, and quantitative measurement and adjustment capabilities.

Technical Specifications
Parameter Value
Model SP45F-16Q
Test Pressure 2.4 MPa (24 kgf/cm²)
Working Pressure ≤1.6 MPa (16 kgf/cm²)
Operating Temperature -10℃ to 100℃
Media Water
Characteristic Curve Equal Percentage
Installation Scope Main trunk lines, branch lines, indoor water supply mains, branch risers, and multiple boiler systems
Installation Requirements
  • Install sufficient length of branch pipe sections before and after the static balance valve to ensure rated flow output
  • Verify installation position per drawings; recommended installation on HVAC system return pipeline
  • Check pipeline water flow direction; install strictly according to valve body flow arrow direction
  • Thoroughly clean pipeline debris before installation; prohibit welding slag, branches, stones, and other debris
  • Avoid excessive deformation and welding angles during pipeline flange welding that affect sealing surface flatness
  • After installation, fully open valve for repeated pipeline flushing until clean; prohibit valve closure during flushing